Belden RG-6 Quad-Shield Digital Cable - per linear foot

Print Belden RG-6 Quad-Shield Digital Cable - per linear foot pageRequest Bulk Pricing CAMCOR ITEM NO. BEL1189A | MFG. PART NO. 1189A
Belden RG-6 Quad-Shield Digital Cable - per linear foot
Belden RG-6 Quad-Shield Digital Cable - per linear foot
Zoom
Close WindowZoom
Alternate View
Your Price: $0.55
Quantity

Product Highlights
18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket.  ... More

Is This Item Right For Me? - Ask Our Experts
Phone 800.868.2462
 
WarningCalifornia Residents:
WARNING: Cancer and reproductive harm - See www.P65Warnings.ca.gov for more information.

Product Description

18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket.

Specifications

Conductor
Number of Coax 1
Total Number of Conductors 1
Series Type Series 6
AWG 18
Stranding Solid
Conductor Diameter .040 in.
Conductor Material BCCS - Bare Copper Covered Steel
Insulation
Insulation Material Gas-injected FPE - Foam Polyethylene
Insulation Diameter .180 in.
Outer Shield
Outer Shield Material Trade Name Duobond® IV
Outer Shield Type Tape/Braid/Tape/Braid
Outer Layer 1
Trade Name Bonded Duofoil®
Type Tape
Material Bonded Aluminum Foil-Polyester Tape-Aluminum Foil
Coverage 100
Outer Layer 2
Type Braid
Material AL-Alumnium
Coverage 60
Outer Layer 3
Trade Name Duofoil
Type Tape
Material Aluminum Foil-Polyester Tape-Aluminum Foil
Coverage 100
Outer Layer 4
Type Braid
Material AL - Aluminum
Coverage 40
Outer Shield Coverage
Percent 100
Overall Nominal Diameter
Overall Nominal Diameter .298 in.
Mechanical Characteristics
Operating Temperature Range -40°C To +80°C
Bulk Cable Weight 32 lbs/1000 ft.
Max. Recommended Pulling Tension 162 lbs.
Min. Bend Radius (Install) 3 in.
Applicable Standards
NEC/(UL) Specification CATV, CM
CEC/C(UL) Specification CM
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy) 1/1/2004
Flame Test
UL Flame Test UL1685 UL Loading
Sweep Test
Sweep Testing 5 MHz - 1 GHz
Plenum/non-plenum
Plenum (Y/N) N
Plenum Number 1189AP
Electrical Characteristics
Nom. Characteristic Impedance 75 Ohms
Nom. Inductance .097 µH/ft
Nom. Capacitance Conductor to Shield 16.2 pF/ft
Nominal Velocity of Propagation 83%
Nominal Delay 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C 28.0 Ohms/1000 ft
Nominal Outer Shield DC Resistance @ 20°C 4.8 Ohms/1000 ft
Minimum Structural Return Loss
Start Frequency (MHz) 5
Stop Frequency (MHz) 1000
Minimum Structural Return Loss (dB) 20
Max. Attenuation
Frequency (MHz) : Max. Attenuation (dB/100) 5 : .67
Frequency (MHz) : Max. Attenuation (dB/100) 55 : 1.60
Frequency (MHz) : Max. Attenuation (dB/100) 211 : 2.87
Frequency (MHz) : Max. Attenuation (dB/100) 270 : 3.24
Frequency (MHz) : Max. Attenuation (dB/100) 300 : 3.43
Frequency (MHz) : Max. Attenuation (dB/100) 350 : 3.72
Frequency (MHz) : Max. Attenuation (dB/100) 400 : 4.00
Frequency (MHz) : Max. Attenuation (dB/100) 450 : 4.26
Frequency (MHz) : Max. Attenuation (dB/100) 550 : 4.71
Frequency (MHz) : Max. Attenuation (dB/100) 750 : 5.59
Frequency (MHz) : Max. Attenuation (dB/100) 870 : 6.00
Frequency (MHz) : Max. Attenuation (dB/100) 1000 : 6.54